Features:
>> Exceptionally high power rating handing
>> 2U rack mounting
>> High slew rate
>> High damping factor
>> Independent volume control for each channel,hospitable operation
>> Minimum 600 watts power handing when bridged operation at 8ohm
>> Automatic clip limiting
>> Low frequency cut point can be selected to fit different load operation
>> Perfect protection,2ohm impedance automatic sensing to accommodate relative parameters to keep consistency and reliability
Front Panel:
Rear Panel:
Specifications:
Rated Power |
|
Stereo mode 8Ω/4Ω |
200W/300W |
Parallel mono 8Ω/4Ω |
200W/300W |
Bridged mono 16Ω/8Ω |
400W/600W |
THD |
<0.05%(10%Rated power) |
Intermodulation distortion |
<0.1%(60Hz/7KHz,10%Rated power) |
Frequency response |
20Hz~20KHz(+0/-0.25dB) |
Phase difference |
<±15° |
Damping factors |
>800(8Ω/100Hz) |
Crosstalk |
-75dB |
S/N ratio |
>108dB(A-Weight) |
Total gain |
32±0.5dB |
Channel gain error |
<0.25dB |
Input sensitivity |
1V |
Switch speed |
>50V/μs |
Input impedance |
unbalanced 10KΩ input, balanced 20KΩ input |
Input connector |
3-pin XLR/6.35 socket |
Output connector |
NL4 binding post |
Cooling method |
four stepless fans, front-to-rear airflow |
Front panel control |
AC power switch, channel 1/ channel 2 gain knob |
Rear panel control |
parallel/stereo/bridge mode option, lowcut/grouding/limit parameter selection |
Front panel indicator |
yellow-bridge, red-overload, green-signal |
Amplifier protection |
short circuit/DC/overheat/overload protection |
Net dimensions |
483×378×88mm |
Net weight |
12Kg |
Power supply |
AC 220V~230V,50~60Hz,250VA |
Environment Temperature |
Working temperature: -10℃~40℃
Storing temperature: -25℃~80℃ |
Environment humidity |
≤90% |
|
|